-40%

LCD Combination Carbon Monoxide Gas Detector Alarm Battery Warning Home Safety

$ 5.53

Availability: 100 in stock
  • Surveillance Technology: Does not apply
  • Battery Included: No
  • Brand: Branded
  • Certification: As Description
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Smart Home Protocol: Does not apply
  • MPN: Does Not Apply
  • Smart Home Compatibility: Does not apply
  • Features: Does not apply
  • All returns accepted: Returns Accepted
  • Number of Zones: Does not apply
  • Origin: Cn(origin)
  • Connectivity: Does not apply
  • Items Included: Alarm
  • Item must be returned within: 60 Days
  • Operating Sound Rating: Does not apply
  • Location: Indoor Only
  • Return shipping will be paid by: Buyer
  • Model: Does not apply
  • Condition: New
  • Power: Does not apply
  • Type: Carbon Monoxide Detector

    Description

    LCD Combination Carbon Monoxide Gas Detector Alarm Battery Warning Home Safety
    About store:
    Shipping
    :
    we ship the items in 2-3 days
    Tracking  :
    orders can be tracked after 5 days
    Delivery    :
    our delivery time is 20-40 days
    (
    If the delivery is delayed, please contact us)
    Return      :
    we accept returns within 30 days from delivery
    Note          :
    If you have any problem with the item, please consider contacting us before you leave a feedback, we will try our best to solve any issue ^^
    Product
    Description:
    Wide detection range and sensitive response, will alarm when the alarm value is reached. The LCD screen displays, when the host detects carbon monoxide leakage, the screen will display the current value according to the gas concentration. (000‑999PPM) Large volume sound and light alarm, using rubidium iron boron strong magnetic horn, the sound can give out 85 decibel high-pitched alarm. Wide range of applications, suitable for kitchens, bathrooms, living rooms, hotels, warehouses, etc. Exquisite and great workmanship, with strict quality control and quality assurance, high safety factor, can be used with peace of mind.
    Features:
    Item Type: Digital Carbon Monoxide Alarm
    Material: ABS+rubidium iron boron strong magnet
    Model: C20A
    Working Voltage: DC3V
    Alarm Current: 80mA
    Quiescent Current: 80uA
    Detection Distance: Omnidirectional (meter)
    Power Supply: 2 x AA batteries(without)
    Sensitivity and Time: 300ppm, alarm within 3 minutes
    Standby Current: <80uA;
    Alarm Current: <80mA
    Working Environment Conditions: 5~400℃, 20~90% R.H.
    When the concentration exceeds 30PPM, the display lights up
    When the concentration reaches 50 PPM, the alarm will start every 60-90 minutes;
    When the concentration reaches 100 PPM, the alarm will start every 10-40 minutes;
    When the concentration reaches 300 PPM, the alarm will start every 3 minutes;
    Scope of Application: Kitchen, bathroom, living room, hotel, warehouse, etc.
    How to Use :
    Step 1
    Installation Guide: Important: This alarm must be installed on the wall, just install it in detail.
    Installation Guide: Important: This alarm must be installed on the wall, just install it in detail.
    Suggested Installation Location:
    1. Recommended to install an alarm on every floor of a multi-storey house, including every bedroom, corridor, finished attic and basement. If the length of the corridor or room exceeds 30 feet (9.1meter), please sound an alarm at both ends of the bedroom corridor or large room. If there is only one alarm, make sure to place it in the hallway or master bedroom outside the main sleeping area. Confirm that the alarm can be heard in all sleeping areas. Find an alarm in every room where someone is sleeping with the door closed. A closed door may prevent the alarm from waking the sleeper.
    2. Install the alarm on the ceiling in the center of the room so that it is closest to all points in the room. Ceiling installation is the first choice in ordinary residential buildings. When installing the alarm on the ceiling, place the alarm at least 4 inches (10 cm) from the side wall (see Figure A).
    3. Install the alarm on the wall, at least 4 inches (10 cm) below the ceiling and a maximum of 12 inches (30.5 cm) below the ceiling (please refer to the figure below).
    Where not to install:
    1. Do not install in the garage, kitchen, furnace room or bathroom! Install at least 15 feet away from any fuel burning equipment.
    2. Do not install within the following 3 feet (0.9meter) range: kitchen or bathroom doors with friction or showers, forced air ducts for heating or cooling, ceilings or ventilators throughout the house or other high airflow areas .
    3. Avoid using in dusty, dirty or greasy places. Dust, grease or household chemicals can contaminate the alarm sensor and cause it to fail to operate properly. Place the alarm where curtains or other objects will not block the sensor. CO must be able to get the sensor to accurately detect these conditions.
    4. Do not install it in the peak of a vaulted ceiling, "A" shaped ceiling or gable roof. Keep away from humid places. Stay at least one foot away from fluorescent lights, otherwise electronic noise may cause nuisance alarms. Extreme temperatures will affect the sensitivity of the CO alarm.
    5. Do not install it in an area where the temperature is lower than 40°F (4.4℃) or higher than 100℉ (37.8℃), far away from doors and window facing the outside.
    Note:
    1. Loudly 85-level siren.
    2. Permanent carbon monoxide sensor.
    3. Powered by 2 AA batteries.
    4. The alarm sound pattern is four short beeps. In alarm mode, the red LED indicator will flash.
    5. "Chi" is emitted every 40 seconds to indicate that the battery is low (need to be replaced)
    6. The Test / Reset button is used to test the electronic components of the device and verify whether the device is operating normally, and to reset the device when a CO alarm occurs.
    7. Alarm storage function: If the machine has issued an alarm and the button is not pressed during this period, press the button, the green LED will flash once per second for one minute, and the peak alarm level will be displayed on the LCD (for C20A) .
    8. Green and red LED indicators indicate normal operation and alarm status.
    9. After turning on, the machine will make a "chi" sound, and the red LED will flash once.
    10. Power saving function: 4 beeps every 5 seconds at the beginning. In 4 minutes, it will change to 4 beeps every minute to save battery.
    11.3-digit LCD is optional. "LB" on the LCD indicates that the battery is low (need to be replaced), and "990PPM" on the LCD indicates that the CO level exceeds 990ppm. Under normal circumstances, the LCD does not light up. It will light up when the test/reset button is pressed and the CO concentration exceeds 30ppm. (For C20A)
    Please keep the air dry for a few minutes when starting up. Otherwise, the unit will keep beeping and “Err” will be displayed on the LCD screen. If it is, go to an open place and reinstall the battery. Still beeping all the time. Within 1 minute after installing the battery, the machine starts to detect CO.
    Green LED: The green LED flashes once every 40 seconds, indicating that the device is operating normally.
    Red LED: When a dangerous level of carbon monoxide is detected, the red LED will flash and an alarm will sound.
    The carbon monoxide (CO) alarm monitors lots of carbon monoxide in the air. When there is a large amount of carbon monoxide, the alarm will sound with flashing red LED lights.
    Note: This alarm will only indicate lots of carbon monoxide in the sensor. Carbon monoxide gas may be present in other areas.
    Package Included:
    1 x Carbon Monoxide Alarm
    4 x Accessories
    1 x User Manual